Preview

Journal of radiology and nuclear medicine

Advanced search

EXPERIENCE WITH VIRTUAL SONOGRAPHY OF THE BREAST

https://doi.org/10.20862/0042-4676-2014-0-1-23-32

Abstract

Objective: to assess the capabilities of and the first experience with an ACUSON S2000 automated breast volume scanner (ABVS) (Siemens, Germany) to detect abnormal breast lumps. Material and methods. Examinations were made in 97 patients who underwent radiological studies encompassing digital mammography, B-mode ultrasonography of the breast, and its pathomorphological examination. All the cases were classified according to the BI-RADS system. Abnormal breast lumps (BI-RADS 1) were not found in 27 cases; clearly defined benign masses (BI-RADS 2) were detected in 18, and pathomorphologically verified breast cancer (BC) (BI-RADS 5) in 29 cases. All the patients also underwent breast ultrasonography using an ACUSON S2000 system (Siemens, Germany). The results of ABVS examination were compared with those of standard comprehensive breast radiologic examination. Having no preliminary additional information on each patient, an independent expert – a radiologic diagnostician appraised all ultrasound scanning data at a special review station. Results. The sensitivity of the automated scanning assay in detecting breast abnormalities was 100%; its specificity and diagnostic accuracy were 40 and 88%, respectively. The independent expert established the diagnosis of BC in 26 (90%) of the 29 cases. According to the results of automated breast scanning, pre-examination using a set of radiation methods was recommended in 66 (66%) cases. The hyperdiagnosis was 24%. Conclusion. Taking into consideration the fact that none of the BC case was overlooked, the first experience with ABVS showed encouraging results and the need for further clinical tests of the automated breast scanning system.

About the Authors

O. E. Yakobs
P.A. Herzen Moscow Cancer Research Institute, Ministry of Health of the RF, Vtoroy Botkinskiy proezd, 3, Moscow, 125284, Russian Federation
Russian Federation

MD, PhD, Senior Researcher



N. I. Rozhkova
P.A. Herzen Moscow Cancer Research Institute, Ministry of Health of the RF, Vtoroy Botkinskiy proezd, 3, Moscow, 125284, Russian Federation
Russian Federation

MD, PhD, DSc, Professor, Chief of National Center of Oncology of Reproductive Organs (Mammalogy, Gynecology, Andrology, Urology), P.A. Herzen Moscow Cancer Research Institute



M. L. Mazo
P.A. Herzen Moscow Cancer Research Institute, Ministry of Health of the RF, Vtoroy Botkinskiy proezd, 3, Moscow, 125284, Russian Federation
Russian Federation

MD, PhD, Senior Researcher



S. Yu. Mikushin
Clinic OAO "Gazprom", ul. Nametkina, 16, Moscow, 117420, Russian Federation
Russian Federation

Radiologist



References

1. Rozhkova N.I. (ed.) Radiology in mammalogy: Guidance. Moscow: SIMK; 2013 (in Russian).

2. Rozhkova N.I., Gorshkov V.A., Meskikh E.V., Mazo M.L., Prokopenko S.P., Kireeva M.N. et al. Digital Breast Clinic: Visualization technologies. Moscow: SIMK; 2012 (in Russian).

3. Egan R.L., Egan K.L. Automated water-path full-breast sonography: correlation with histology of 176 solid lesions. Am. J. Roentgenol. 1984; 143: 499–507.

4. Kelly K.M., Dean J., Lee S.J., Co-mulada W.S. Breast cancer detection: radiologists’ performance using mammography with and without automated whole-breast ultrasound. Eur. Radiol. 2010; 20: 2557–64.

5. Maturo V.G., Zusmer N.R., Gil-son A.J. et al. Ultrasound of the whole breast utilizing a dedicated automated breast scanner. Radiology. 1980; 137: 457–63.

6. Wenkel E., Heckmann M., Hein-rich M., et al. Automated breast ultrasound: lesion detection and BI-RADS classification – a pilot study. Rofo. 2008; 180: 804–8.

7. Wojcinski S., Farrokh A., Hille U., Wiskirchen J. et al. Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. Int. J. Womens. Health. 2011; 3: 337–46.

8. Kharchenko V.P., Rozhkova N.I. (eds) Mammalogy: National guidance. Moscow: GEOTAR-Media; 2009 (in Russian).

9. Mendelson E.B., Baum J.K., Berg W.A. et al. BI-RADS: Ultrasound. In: D’Orsi C.J., Mendelson E.B., Ikeda D.M. et al. (eds). Breast imaging reporting and data system: ACR BI-RADS – Breast Imaging Atlas. Reston., VA: American College of Radiology; 2003.

10. Kusano A.S., Trichopoulos D., Terry K.L., Chen W.Y., Willet W.C., Michels K.B. A prospective study of breast size and premenopausal breast cancer incidence. Int. J. Cancer. 2006; 118: 2031–4.

11. Wright M.C. Graphical analysis of bra size calculation procedures. Int. J. Cloth. Sci. Technol. 2002; 14: 41–5. Поступила 22.01.2013


Review

For citations:


Yakobs O.E., Rozhkova N.I., Mazo M.L., Mikushin S.Yu. EXPERIENCE WITH VIRTUAL SONOGRAPHY OF THE BREAST. Journal of radiology and nuclear medicine. 2014;(1):23-32. (In Russ.) https://doi.org/10.20862/0042-4676-2014-0-1-23-32

Views: 651


ISSN 0042-4676 (Print)
ISSN 2619-0478 (Online)