Preview

Journal of radiology and nuclear medicine

Advanced search

Pulmonary nodules volumetry. Variability in Results After Manual Correction of Contours

https://doi.org/10.20862/0042-4676-2019-100-2-74-81

Abstract

Objective. To study variability of volumetric of the pulmonary nodules volumetry after manual correction of their contours.

Material and methods. Twenty-seven nodules uncircumscribed from the vascular structures and pleura were selected. A linear regression model was used to investigate the impact of the size of a nodule, the area of its contact with the adjacent structures on variability in results.

Results. The linear regression model based on contact area and nodule size can correctly predict volumetry variability.

Conclusion. Even after manual segmentation volumetry remain suitable method for size assessment of lung nodules. Segmentation should be made with the same person because of significant difference of interobserver and intraobserver variabilities.

About the Authors

E. V. Rozengauz
North-Western State Medical University named after I.I. Mechnikov, Ministry of Health of the Russian Federation; Russian Scientific Center of Radiology and Surgical Technologies named after A.M. Granov, Ministry of Health of the Russian Federation
Russian Federation

Evgeniy V. Rozengauz, Dr. Med. Sc., Professor of Chair of Radiology and Radiotherapy, North-Western State Medical University named after I.I. Mechnikov, Ministry of Health of the Russian Federation; Head of Department of Computed Tomography, Russian Scientific Center of Radiology and Surgical Technologies named after A.M. Granov, Ministry of Health of the Russian Federation

ul. Kirochnaya, 41, St. Petersburg, 191015, 

ul. Leningradskaya, 70, poselok Pesochnyy, St. Petersburg, 197758



D. V. Nesterov
North-Western State Medical University named after I.I. Mechnikov, Ministry of Health of the Russian Federation
Russian Federation

Denis V. Nesterov, Cand. Med. Sc., Assistant Professor of Chair of Radiology and Radiotherapy

ul. Kirochnaya, 41, St. Petersburg, 191015



Z. A. Al’derov
North-Western State Medical University named after I.I. Mechnikov, Ministry of Health of the Russian Federation
Russian Federation

Zaur A. Al’derov, Postgraduate

ul. Kirochnaya, 41, St. Petersburg, 191015



N. M. Korablin
City Hospital № 33
Russian Federation

Nikolay M. Korablin, Cand. Med. Sc., Radiologist

ul. Pavlovskaya, 16A, St. Petersburg, 196653



References

1. Therasse P., Arbuck S.G., Eisenhauer E.A., Wanders J., Kaplan R.S., Rubinstein L. et al. New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J. Natl. Cancer. Inst. 2000; 92 (3): 205–16.

2. Eisenhauer E.A., Therasse P., Bogaerts J., Schwartz L.H., Sargent D., Ford R. et al. New Response Evaluation Criteria in Solid Tumours: Revised RECIST Guideline (Version 1.1). Eur. J. Cancer. 2009; 45 (2): 228–47.

3. Frenette A., Morrell J., Bjella K., Fogarty E., Beal J., Chaudhary V. Do diametric measurements provide sufficient and reliable tumor assessment? An evaluation of diametric, areametric, and volumetric variability of lung lesion measurements on computerized tomography scans. J. Oncol. 2015; 2015: 632943. DOI: 10.1155/2015/632943

4. Obuchowski N.A., Reeves A.P., Huang E.P., Wang X.F., Buckler A.J., Kim H.J. et al. Quantitative imaging biomarkers: a review of statistical methods for computer algorithm comparisons. Stat. Methods Med. Res. 2015; 24 (1): 68–106.

5. Wang Y., van Klaveren R.J., van der Zaag-Loonen H.J., de Bock G.H., Gietema H.A., Xu D.M. et al. Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program. Radiology. 2008; 248 (2): 625–31.

6. Wormanns D., Kohl G., Klotz E., Marheine A., Beyer F., Heindel W., Diederich S. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur. Radiol. 2004; 14 (1): 86–92.


Review

For citations:


Rozengauz E.V., Nesterov D.V., Al’derov Z.A., Korablin N.M. Pulmonary nodules volumetry. Variability in Results After Manual Correction of Contours. Journal of radiology and nuclear medicine. 2019;100(2):74-81. (In Russ.) https://doi.org/10.20862/0042-4676-2019-100-2-74-81

Views: 1364


ISSN 0042-4676 (Print)
ISSN 2619-0478 (Online)