<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">rentrad</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник рентгенологии и радиологии</journal-title><trans-title-group xml:lang="en"><trans-title>Journal of radiology and nuclear medicine</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0042-4676</issn><issn pub-type="epub">2619-0478</issn><publisher><publisher-name>Limited Liability Company "LUCHEVAYA DIAGNOSTIKA", Russian Association of Radiologists</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.20862/0042-4676-2021-102-4-255-262</article-id><article-id custom-type="elpub" pub-id-type="custom">rentrad-660</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEWS</subject></subj-group></article-categories><title-group><article-title>Актуальные вопросы рационального применения йодсодержащих контрастных средств в лучевой диагностике</article-title><trans-title-group xml:lang="en"><trans-title>Topical Issues of Rational Use of Iodine-Containing Contrast Agents in X-Ray Diagnostics</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8887-4420</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шимановский</surname><given-names>Н. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Shimanovskiy</surname><given-names>N. L.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Шимановский Николай Львович, д. м. н., профессор, чл.-корр. РАН, заведующий кафедрой молекулярной фармакологии и радиобиологии им. академика П.В. Сергеева </p><p>ул. Островитянова, 1, Москва, 117997 </p></bio><bio xml:lang="en"><p>Nikolay L. Shimanovskiy, Dr. Med. Sc., Professor, Corresponding Member of RAS, Chief of Chair of Molecular Pharmacology and Radiobiology </p><p>ul. Ostrovityanova, 1, Moscow, 117997 </p></bio><email xlink:type="simple">shimannn@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГАОУ ВО «Российский национальный исследовательский медицинский университет им. Н.И. Пирогова» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Pirogov Russian National Research Medical University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2021</year></pub-date><pub-date pub-type="epub"><day>15</day><month>09</month><year>2021</year></pub-date><volume>102</volume><issue>4</issue><fpage>255</fpage><lpage>262</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Шимановский Н.Л., 2021</copyright-statement><copyright-year>2021</copyright-year><copyright-holder xml:lang="ru">Шимановский Н.Л.</copyright-holder><copyright-holder xml:lang="en">Shimanovskiy N.L.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.russianradiology.ru/jour/article/view/660">https://www.russianradiology.ru/jour/article/view/660</self-uri><abstract><p>Рассмотрены возможности рационального применения йодированных рентгеноконтрастных средств при компьютерной томографии и чрескожных коронарных вмешательствах с учетом пути, способа их введения и вязкости растворов. При фиксировании скорости введения йода и температуры вводимого раствора необходимое давление введения рентгеноконтрастных средств определяется вязкостью раствора.</p></abstract><trans-abstract xml:lang="en"><p>The possibilities of rational use of iodine radiopaque agents in computed tomography and percutaneous coronary interventions are considered, taking into account the route, method of their administration and the viscosity of their solutions. When fixing the rate of iodine administration and the temperature of the injected solution, the required injection pressure of the contrast media is determined by the solution viscosity.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>йодированные рентгеноконтрастные средства</kwd><kwd>компьютерная томография</kwd><kwd>йопромид</kwd><kwd>обзор</kwd></kwd-group><kwd-group xml:lang="en"><kwd>iodine radiopaque agents</kwd><kwd>computed tomography</kwd><kwd>iopromide</kwd><kwd>review</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Schöckel L, Jost G, Seidensticker P, et al. Developments in X-Ray contrast media and the potential impact on computed tomography. Invest Radiol. 2020; 55(9): 592–7. https://doi.org/10.1097/RLI.0000000000000696.</mixed-citation><mixed-citation xml:lang="en">Schöckel L, Jost G, Seidensticker P, et al. Developments in X-Ray contrast media and the potential impact on computed tomography. Invest Radiol. 2020; 55(9): 592–7. https://doi.org/10.1097/RLI.0000000000000696.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Ojeda S, Romaguera R, Cruz-González I, Moreno R. Spanish Cardiac Catheterization and Coronary Intervention Registry. 29th Official Report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990–2019). Rev Esp Cardiol (Engl Ed). 2020; 73(11): 927–36. https://doi.org/10.1016/j.rec.2020.09.005.</mixed-citation><mixed-citation xml:lang="en">Ojeda S, Romaguera R, Cruz-González I, Moreno R. Spanish Cardiac Catheterization and Coronary Intervention Registry. 29th Official Report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990–2019). Rev Esp Cardiol (Engl Ed). 2020; 73(11): 927–36. https://doi.org/10.1016/j.rec.2020.09.005.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">ESUR Guidelines on contrast agents. European Society of Urogenital Radiology. Available at: http://www.esur.org/fileadmin/content/2019/ESUR_ Guidelines_10.0_Final_Version.pdf (accessed June 17, 2021).</mixed-citation><mixed-citation xml:lang="en">ESUR Guidelines on contrast agents. European Society of Urogenital Radiology. Available at: http://www.esur.org/fileadmin/content/2019/ESUR_ Guidelines_10.0_Final_Version.pdf (accessed June 17, 2021).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Suh YJ, Yoon SH, Hong H, et al. Acute adverse reactions to nonionic iodinated contrast media: a meta-analysis. Invest Radiol. 2019; 54(9): 589–99. https://doi.org/10.1097/RLI.0000000000000568.</mixed-citation><mixed-citation xml:lang="en">Suh YJ, Yoon SH, Hong H, et al. Acute adverse reactions to nonionic iodinated contrast media: a meta-analysis. Invest Radiol. 2019; 54(9): 589–99. https://doi.org/10.1097/RLI.0000000000000568.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Чучалин А.Г., Яснецов В.В. (ред.) Федеральное руководство по использованию лекарственных средств (формулярная система). Вып. 17. М.; 2016: 942–6. [Chuchalin АG, Yasnetsov VV (Eds) Federal guidelines for the use of drugs (formulary system). Issue 17. Мoscow; 2016: 942–6 (in Russ.).]</mixed-citation><mixed-citation xml:lang="en">Чучалин А.Г., Яснецов В.В. (ред.) Федеральное руководство по использованию лекарственных средств (формулярная система). Вып. 17. М.; 2016: 942–6. [Chuchalin АG, Yasnetsov VV (Eds) Federal guidelines for the use of drugs (formulary system). Issue 17. Мoscow; 2016: 942–6 (in Russ.).]</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Palkowitsch PK, Bostelmann S, Lengsfeld P. Safety and tolerability of iopromide intravascular use: a pooled analysis of three non-interventional studies in 132,012 patients. Acta Radiol. 2014; 55(6): 707–14. https://doi.org/10.1177/0284185113504753.</mixed-citation><mixed-citation xml:lang="en">Palkowitsch PK, Bostelmann S, Lengsfeld P. Safety and tolerability of iopromide intravascular use: a pooled analysis of three non-interventional studies in 132,012 patients. Acta Radiol. 2014; 55(6): 707–14. https://doi.org/10.1177/0284185113504753.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Chen JY, Liu Y, Zhou YL, et al. Safety and tolerability of iopromide in patients undergoing cardiac catheterization: realworld multicenter experience with 17,513 patients from the TRUST trial. Int J Cardiovasc Imaging. 2015; 31(7): 1281–91. https://doi.org/10.1007/s10554-015-0688-9.</mixed-citation><mixed-citation xml:lang="en">Chen JY, Liu Y, Zhou YL, et al. Safety and tolerability of iopromide in patients undergoing cardiac catheterization: realworld multicenter experience with 17,513 patients from the TRUST trial. Int J Cardiovasc Imaging. 2015; 31(7): 1281–91. https://doi.org/10.1007/s10554-015-0688-9.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Rengo M, Dharampal A, Lubbers M, et al. Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON). Eur Radiol. 2019; 29(11): 6109–18. https://doi.org/10.1007/s00330-019-06196-7.</mixed-citation><mixed-citation xml:lang="en">Rengo M, Dharampal A, Lubbers M, et al. Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON). Eur Radiol. 2019; 29(11): 6109–18. https://doi.org/10.1007/s00330-019-06196-7.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">García M, Aguirre U, Martinez A, et al. Acute adverse reactions to iopromide vs iomeprol: a retrospective analysis of spontaneous reporting from a radiology department. Br J Radiol. 2014; 87(1033): 20130511. https://doi.org/10.1259/bjr.20130511.</mixed-citation><mixed-citation xml:lang="en">García M, Aguirre U, Martinez A, et al. Acute adverse reactions to iopromide vs iomeprol: a retrospective analysis of spontaneous reporting from a radiology department. Br J Radiol. 2014; 87(1033): 20130511. https://doi.org/10.1259/bjr.20130511.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Kok M, Mihl C, Hendriks BM, et al. Patient comfort during contrast media injection in coronary computed tomographic angiography using varying contrast media concentrations and flow rates: results from the EICAR Trial. Invest Radiol. 2016; 51(12): 810–15. https://doi.org/10.1097/RLI.0000000000000284.</mixed-citation><mixed-citation xml:lang="en">Kok M, Mihl C, Hendriks BM, et al. Patient comfort during contrast media injection in coronary computed tomographic angiography using varying contrast media concentrations and flow rates: results from the EICAR Trial. Invest Radiol. 2016; 51(12): 810–15. https://doi.org/10.1097/RLI.0000000000000284.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Halsell RD. Heating contrast media: role in contemporary angiography. Radiology. 1987; 164: 276–8. https://doi.org/10.1148/radiology.164.1.3588919.</mixed-citation><mixed-citation xml:lang="en">Halsell RD. Heating contrast media: role in contemporary angiography. Radiology. 1987; 164: 276–8. https://doi.org/10.1148/radiology.164.1.3588919.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Chaya A, Jost G, Endrikat J. Piston-based vs peristaltic pumpbased ct injector systems. Radiol Technol. 2019; 90(4): 344–52.</mixed-citation><mixed-citation xml:lang="en">Chaya A, Jost G, Endrikat J. Piston-based vs peristaltic pumpbased ct injector systems. Radiol Technol. 2019; 90(4): 344–52.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Wildberger JE, Mahnken AH, Seidensticker PR. Aorto-peripheral MDCT angiography: implications for contrast medium delivery. Imaging Decisions. 2007; 4: 8–12. https://doi.org/10.1111/j.1617-0830.2007.00109.x.</mixed-citation><mixed-citation xml:lang="en">Wildberger JE, Mahnken AH, Seidensticker PR. Aorto-peripheral MDCT angiography: implications for contrast medium delivery. Imaging Decisions. 2007; 4: 8–12. https://doi.org/10.1111/j.1617-0830.2007.00109.x.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">ACR Manual on Contrast Media 2021. ACR Committee on Drugs and Contrast Media. Available at: https://www.acr.org/-/media/ACR/files/clinical-resources/ contrast_media.pdf (accessed June 17, 2021).</mixed-citation><mixed-citation xml:lang="en">ACR Manual on Contrast Media 2021. ACR Committee on Drugs and Contrast Media. Available at: https://www.acr.org/-/media/ACR/files/clinical-resources/ contrast_media.pdf (accessed June 17, 2021).</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Hendriks BM, Kok M, Mihl C, et al. Individually tailored contrast enhancement in CT pulmonary angiography. Br J Radiol. 2016; 89: 20150850. https://doi.org/10.1259/bjr.20150850.</mixed-citation><mixed-citation xml:lang="en">Hendriks BM, Kok M, Mihl C, et al. Individually tailored contrast enhancement in CT pulmonary angiography. Br J Radiol. 2016; 89: 20150850. https://doi.org/10.1259/bjr.20150850.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Endrikat J, Michel A, Kölbach R, et al. Risk of hypersensitivity reactions to iopromide after intra-arterial versus intravenous administration: a nested case-control analysis of 133,331 patients. Invest Radiol. 2020; 55(1): 38–44. https://doi.org/10.1097/RLI.0000000000000611.</mixed-citation><mixed-citation xml:lang="en">Endrikat J, Michel A, Kölbach R, et al. Risk of hypersensitivity reactions to iopromide after intra-arterial versus intravenous administration: a nested case-control analysis of 133,331 patients. Invest Radiol. 2020; 55(1): 38–44. https://doi.org/10.1097/RLI.0000000000000611.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Cha MJ, Kang DY, Lee W, et al. Hypersensitivity reactions to iodinated contrast media: a multicenter study of 196 081 patients. Radiology. 2019; 293(1): 117–24. https://doi.org/10.1148/radiol.2019190485.</mixed-citation><mixed-citation xml:lang="en">Cha MJ, Kang DY, Lee W, et al. Hypersensitivity reactions to iodinated contrast media: a multicenter study of 196 081 patients. Radiology. 2019; 293(1): 117–24. https://doi.org/10.1148/radiol.2019190485.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang B, Liu J, Dong Y, et al. Extrinsic warming of lowosmolality iodinated contrast media to 37 °C reduced the rate of allergic-like reaction. Allergy Asthma Proc. 2018; 39(6): e55–63. https://doi.org/10.2500/aap.2018.39.4160.</mixed-citation><mixed-citation xml:lang="en">Zhang B, Liu J, Dong Y, et al. Extrinsic warming of lowosmolality iodinated contrast media to 37 °C reduced the rate of allergic-like reaction. Allergy Asthma Proc. 2018; 39(6): e55–63. https://doi.org/10.2500/aap.2018.39.4160.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Sodagari F, Mozaffary A, Wood CG 3rd, et al. Reactions to both nonionic iodinated and gadolinium-based contrast media: incidence and clinical characteristics. AJR Am J Roentgenol. 2018; 210(4): 715–9. https://doi.org/10.2214/AJR.17.18655.</mixed-citation><mixed-citation xml:lang="en">Sodagari F, Mozaffary A, Wood CG 3rd, et al. Reactions to both nonionic iodinated and gadolinium-based contrast media: incidence and clinical characteristics. AJR Am J Roentgenol. 2018; 210(4): 715–9. https://doi.org/10.2214/AJR.17.18655.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Kim SR, Lee JH, Park KH, et al. Varied incidence of immediate adverse reactions to low-osmolar non-ionic iodide radiocontrast media used in computed tomography. Clin Exp Allergy. 2017; 47(1): 106–12. https://doi.org/10.1111/cea.12803.</mixed-citation><mixed-citation xml:lang="en">Kim SR, Lee JH, Park KH, et al. Varied incidence of immediate adverse reactions to low-osmolar non-ionic iodide radiocontrast media used in computed tomography. Clin Exp Allergy. 2017; 47(1): 106–12. https://doi.org/10.1111/cea.12803.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Dillman JR, Strouse PJ, Ellis JH, et al. Incidence and severity of acute allergic-like reactions to i.v. nonionic iodinated contrast material in children. AJR Am J Roentgenol. 2007; 188(6): 1643–7. https://doi.org/10.2214/AJR.06.1328.</mixed-citation><mixed-citation xml:lang="en">Dillman JR, Strouse PJ, Ellis JH, et al. Incidence and severity of acute allergic-like reactions to i.v. nonionic iodinated contrast material in children. AJR Am J Roentgenol. 2007; 188(6): 1643–7. https://doi.org/10.2214/AJR.06.1328.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Kopp AF, Mortele KJ, Cho YD, et al. Prevalence of acute reactions to iopromide: postmarketing surveillance study of 74,717 patients. Acta Radiol. 2008; 49(8): 902–11. https://doi.org/10.1080/02841850802282811.</mixed-citation><mixed-citation xml:lang="en">Kopp AF, Mortele KJ, Cho YD, et al. Prevalence of acute reactions to iopromide: postmarketing surveillance study of 74,717 patients. Acta Radiol. 2008; 49(8): 902–11. https://doi.org/10.1080/02841850802282811.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Schild H. CM, to see or not to see. Schering Diagnositics, Bayer. 1994. Last update 2018. Available at: https://www.librarything.com/work/10548853 (accessed June 17, 2021).</mixed-citation><mixed-citation xml:lang="en">Schild H. CM, to see or not to see. Schering Diagnositics, Bayer. 1994. Last update 2018. Available at: https://www.librarything.com/work/10548853 (accessed June 17, 2021).</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Guéant-Rodriguez RM, Romano A, Barbaud A, et al. Hypersensitivity reactions to iodinated contrast media. Curr Pharm Des. 2006; 12(26): 3359–72. https://doi.org/10.2174/138161206778193999.</mixed-citation><mixed-citation xml:lang="en">Guéant-Rodriguez RM, Romano A, Barbaud A, et al. Hypersensitivity reactions to iodinated contrast media. Curr Pharm Des. 2006; 12(26): 3359–72. https://doi.org/10.2174/138161206778193999.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">From AM, Al Badarin FJ, McDonald FS, et al. Iodixanol versus low-osmolar contrast media for prevention of contrast induced nephropathy: meta-analysis of randomized, controlled trials. Circ Cardiovasc Interv. 2010; 3(4): 351–8. https://doi.org/10.1161/CIRCINTERVENTIONS.109.917070.</mixed-citation><mixed-citation xml:lang="en">From AM, Al Badarin FJ, McDonald FS, et al. Iodixanol versus low-osmolar contrast media for prevention of contrast induced nephropathy: meta-analysis of randomized, controlled trials. Circ Cardiovasc Interv. 2010; 3(4): 351–8. https://doi.org/10.1161/CIRCINTERVENTIONS.109.917070.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Nijssen EC, Rennenberg RJ, Nelemans PJ, et al. Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrastinduced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial. Lancet. 2017; 389(10076): 1312–22. https://doi.org/10.1016/S0140-6736(17)30057-0.</mixed-citation><mixed-citation xml:lang="en">Nijssen EC, Rennenberg RJ, Nelemans PJ, et al. Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrastinduced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial. Lancet. 2017; 389(10076): 1312–22. https://doi.org/10.1016/S0140-6736(17)30057-0.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Nijssen EC, Nelemans PJ, Rennenberg RJ, et al. prophylactic intravenous hydration to protect renal function from intravascular iodinated contrast material (AMACING): longterm results of a prospective, randomised, controlled trial. EClinicalMedicine. 2018; 4–5: 109–16. https://doi.org/10.1016/j.eclinm.2018.10.007.</mixed-citation><mixed-citation xml:lang="en">Nijssen EC, Nelemans PJ, Rennenberg RJ, et al. prophylactic intravenous hydration to protect renal function from intravascular iodinated contrast material (AMACING): longterm results of a prospective, randomised, controlled trial. EClinicalMedicine. 2018; 4–5: 109–16. https://doi.org/10.1016/j.eclinm.2018.10.007.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
