<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">rentrad</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник рентгенологии и радиологии</journal-title><trans-title-group xml:lang="en"><trans-title>Journal of radiology and nuclear medicine</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0042-4676</issn><issn pub-type="epub">2619-0478</issn><publisher><publisher-name>Limited Liability Company "LUCHEVAYA DIAGNOSTIKA", Russian Association of Radiologists</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.20862/0042-4676-2016-97-3-165-172</article-id><article-id custom-type="elpub" pub-id-type="custom">rentrad-141</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>В ПОМОЩЬ ПРАКТИКУЮЩЕМУ ВРАЧУ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>GUIDELINES FOR THE PRACTITIONER</subject></subj-group></article-categories><title-group><article-title>Преимущества применения автоматического инъектора MEDRAD® Avanta с технологией ручного управления введения контрастного средства в интервенционной радиологии</article-title><trans-title-group xml:lang="en"><trans-title>Advantages of automatic injector MEDRAD® Avanta with manual operation of contrast agent injection in interventional radiology</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Осиев</surname><given-names>А. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Osiev</surname><given-names>A. G.</given-names></name></name-alternatives><bio xml:lang="ru"><p>д. м. н., профессор, заведующий отделом рентгенохирургии сердца и сосудов</p></bio><bio xml:lang="en"><p>MD, PhD, DSc, Professor, Head of Department of Roentgen Surgery of the Heart and Vessels</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шимановский</surname><given-names>Н. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Shimanovskii</surname><given-names>N. L.</given-names></name></name-alternatives><bio xml:lang="ru"><p>д. м. н., профессор, чл.-корр. РАН, заведующий кафедрой молекулярной фармакологии и радиобиологии им. академика П.В. Сергеева</p></bio><bio xml:lang="en"><p>MD, PhD, DSc, Professor, Corresponding Member of Russian Academy of Sciences, Head of P.V. Sergeev Department of Molecular Pharmacology and Radiobiology</p></bio><email xlink:type="simple">shimannn@yandex.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ГБУЗ МО «Московский областной научно-исследовательский клинический институт им. М.Ф. Владимирского» Министерства здравоохранения Московской области, ул. Щепкина, 61/2, корп. 1, Москва, 129110, Российская Федерация</institution><country>Россия</country></aff><aff xml:lang="en"><institution>M.F. Vladimirsky Moscow Regional Research Clinical Institute, Ministry of Health of the Moscow region, ul. Shchepkina, 61/2, korpus 1, Moscow, 129110, Russian Federation</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ГБОУ ВПО «Российский национальный исследовательский медицинский университет имени Н.И. Пирогова» Министерства здравоохранения РФ, ул. Островитянова, 1, Москва, 117997, Российская Федерация</institution><country>Россия</country></aff><aff xml:lang="en"><institution>N.I. Pirogov Russian National Research Medical University, Ministry of Health of the RF, ul. Ostrovityanova, 1, Moscow, 117997, Russian Federation</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>20</day><month>07</month><year>2016</year></pub-date><volume>97</volume><issue>3</issue><fpage>165</fpage><lpage>172</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Осиев А.Г., Шимановский Н.Л., 2016</copyright-statement><copyright-year>2016</copyright-year><copyright-holder xml:lang="ru">Осиев А.Г., Шимановский Н.Л.</copyright-holder><copyright-holder xml:lang="en">Osiev A.G., Shimanovskii N.L.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.russianradiology.ru/jour/article/view/141">https://www.russianradiology.ru/jour/article/view/141</self-uri><abstract><p>Описаны преимущества применения автоматического инъектора MEDRAD® Avanta в интервенционной радиологии. Рассмотрены вопросы выбора наиболее оптимального рентгеноконтрастного средства при проведении ангиографии и рентгеноэндоваскулярных вмешательств. Сделан вывод, что контрастирование с помощью йопромида и автоматического инъектора MEDRAD® Avanta следует считать надежным, высокоэффективным и безопасным методом визуализации в диагностике и рентгенохирургии сердечно-сосудистой патологии, при мальформациях, опухолях, пороках развития и при других заболеваниях.</p></abstract><trans-abstract xml:lang="en"><p>Advantages of automatic injector MEDRAD® Avanta in interventional radiology are described. The issues concerning the selection of the optimal contrast agent during angiography and endovascular interventions are considered. It is concluded that contrast enhancement with iopromide and automatic injector MEDRAD® Avanta should be considered as reliable, highly effective and safe imaging technique in the diagnosis and X-ray surgery in cardiovascular diseases, malformations, tumors and other patology</p></trans-abstract><kwd-group xml:lang="ru"><kwd>автоматический инъектор MEDRAD® Avanta</kwd><kwd>интервенционная радиология</kwd><kwd>йопромид</kwd></kwd-group><kwd-group xml:lang="en"><kwd>automatic injector MEDRAD® Avanta</kwd><kwd>interventional radiology</kwd><kwd>iopromide</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Sandhu K., Nadar S.K. Percutaneous coronary intervention in the elderly. Int. J. Cardiol. 2015; 199: 342–55.</mixed-citation><mixed-citation xml:lang="en">Sandhu K., Nadar S.K. Percutaneous coronary intervention in the elderly. Int. J. Cardiol. 2015; 199: 342–55.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Шимановский Н.Л. Контрастные средства. Руководство по рациональному применению. М.: ГЭОТАР-Медиа; 2009: 463.</mixed-citation><mixed-citation xml:lang="en">Shimanovskii N.L. Contrast agents. Guide rational use. Moscow: GEOTAR-Media; 2009: 463 (in Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Поляев Ю.А., Гарбузов Р.В. Использование автоматического инъектора MARK V PRO VIS (MEDRAD) при проведении эндоваскулярных процедур в детской практике. Диагностическая и интервенционная радиология. 2009; 3 (2): 47–54.</mixed-citation><mixed-citation xml:lang="en">Polyaev Yu.A., Garbuzov R.V. Use of automatic injector MARK V PRO VIS (MEDRAD) for endovascular interventions in children. Diagnosticheskaya i Interventsionnaya Radiologiya. 2009; 3 (2): 47–54 (in Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Kaluski E., Moussa I.D., Heuser R. R., Kern M.J. Automated contrast injectors for angiography: Devices, methodology, and safety. Cathet. Cardiovasc. Interv. 2009; 74: 459– 64.</mixed-citation><mixed-citation xml:lang="en">Kaluski E., Moussa I.D., Heuser R. R., Kern M.J. Automated contrast injectors for angiography: Devices, methodology, and safety. Cathet. Cardiovasc. Interv. 2009; 74: 459–64.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Avanta™ Fluid Management Injection System. Available at: http://www.radiologysolutions.bayer.com /products/angiography/injection/avanta/</mixed-citation><mixed-citation xml:lang="en">Avanta™ Fluid Management Injection System. Available at: http:// www.radiologysolutions.bayer.com/products/angiography/injection/avanta/</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Кармазановский Г.Г., Поляев Ю.А., Юдин А.Л., Шимановский Н.Л. Современные рентгеноконтрастные средства и нефропатия: как снизить риск развития почечной недостаточности? Медицинская визуализация. 2007; 1: 135–44.</mixed-citation><mixed-citation xml:lang="en">Karmazanovskii G.G., Polyaev Yu.A., Yudin A.L., Shimanovskii N.L. Modern contrast  media and nefropathy: How to decrease the risk of renal failure? Meditsinskaya  Vizualizatsiya. 2007; 1: 135–44 (in Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Brunette J., Mongrain R., Roders-Cabau J., Larose E., Leask R., Bertrand O.F. Comparative rheology of low- and iso-osmolarity contrast agents at different temperatures. Catheter. Cardiovasc. Interv. 2008; 71: 78–83.</mixed-citation><mixed-citation xml:lang="en">Brunette J., Mongrain R., Roders-Cabau J., Larose E., Leask R., Bertrand O.F.  Comparative rheology of low- and iso-osmolarity contrast agents at different  temperatures. Catheter. Cardiovasc. Interv. 2008; 71: 78–83.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Halsell R.D. Heating contrast media: Role in contemporary angiography. Radiology. 1987; 164: 276–8.</mixed-citation><mixed-citation xml:lang="en">Halsell R.D. Heating contrast media: Role in contemporary angiography. Radiology.  1987; 164: 276–8.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Wildberger J.E., Mahnken A.H., Seidensticker P.R. Aorto-peripheral MDCT angiography: Implications for contrast medium delivery. Imaging Decisions. 2007; 4: 8–12.</mixed-citation><mixed-citation xml:lang="en">Wildberger J.E., Mahnken A.H., Seidensticker P.R. Aorto-peripheral MDCT  angiography: Implications for contrast medium delivery. Imaging Decisions. 2007; 4:  8–12.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Scutt C. Generic achievable space results. Indianola: Medrad Ltd. Publication; 2008.</mixed-citation><mixed-citation xml:lang="en">Scutt C. Generic achievable space results. Indianola: Medrad Ltd. Publication; 2008.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Call J., Sacrinty M., Applegate R., Little W., Santos R., Baki T. et al. Automated contrast injection in contemporary practice during cardiac catheterization and PCI: Effects on contrast-induced nephropathy. J. Invasive Cardiol. 2006; 18: 469–74.</mixed-citation><mixed-citation xml:lang="en">Call J., Sacrinty M., Applegate R., Little W., Santos R., Baki T. et al. Automated contrast injection in contemporary practice during cardiac  catheterization and PCI: Effects on contrast-induced nephropathy. J. Invasive  Cardiol. 2006; 18: 469–74.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Beг Р.Дж. Линс Дж.А., Каленак Г., Белтц Р., Пфдезанин-Склак Д. Управление инъекциями контрастных препаратов во время диагностических и интервенционных процедур на коронарных сосудах. Диагностическая и интервенционная радиология. 2009; 3 (10): 41–5.</mixed-citation><mixed-citation xml:lang="en">Begg R.J., Lins J.A., Kalenak G., Beltz R., Padezanin-Sklack D. Managing  contrast injections during diagnostic and interventional coronary procedures.  Diagnosticheskaya i Interventsionnaya Radiologiya. 2009; 3 (10): 41–5 (in Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Larsen A.S., Ostera°s B.H. Step back from the patient: Reduction of radiation dose to the operator by the systematic use of an automatic power injector for contrast media in an interventional angiography suite. Acta Radiol. 2012; 53 (3): 330–4.</mixed-citation><mixed-citation xml:lang="en">Larsen A.S., Ostera°s B.H. Step back from the patient: Reduction of radiation</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Durst R., Lotan C., Nassar H., Gotsman M., Mor E., Varshitzki B. et al. Comparison of 4 and 6 French catheters for coronary angiography: Real-world modeling. Isr. Med. Assoc. J. 2007; 9: 290–3.</mixed-citation><mixed-citation xml:lang="en">dose to the operator by the systematic use of an automatic power injector for contrast media in an interventional angiography suite. Acta Radiol. 2012; 53 (3): 330–4.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Anne G., Gruberg L., Huber A., Nikolsky E., Grenadier E., Boulus M. et al. Traditional versus automated injection contrast system in diagnostic and percutaneous coronary interventional procedures: Comparison of the contrast volume delivered. J. Invasive Cardiol. 2004; 16 (7): 360–2.</mixed-citation><mixed-citation xml:lang="en">Durst R., Lotan C., Nassar H., Gotsman M., Mor E., Varshitzki B. et al.  Comparison of 4 and 6 French catheters for coronary angiography: Real-world  modeling. Isr. Med. Assoc. J. 2007; 9: 290–3.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Anne G., Gruberg L., Huber A., Nikolsky E., Grenadier E., Boulus M. et al.  Traditional versus automated injection contrast system in diagnostic and  percutaneous coronary interventional procedures: Comparison of the contrast volume  delivered. J. Invasive Cardiol. 2004; 16 (7): 360–2.</mixed-citation><mixed-citation xml:lang="en">Anne G., Gruberg L., Huber A., Nikolsky E., Grenadier E., Boulus M. et al.  Traditional versus automated injection contrast system in diagnostic and  percutaneous coronary interventional procedures: Comparison of the contrast volume  delivered. J. Invasive Cardiol. 2004; 16 (7): 360–2.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
