<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">rentrad</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник рентгенологии и радиологии</journal-title><trans-title-group xml:lang="en"><trans-title>Journal of radiology and nuclear medicine</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0042-4676</issn><issn pub-type="epub">2619-0478</issn><publisher><publisher-name>Limited Liability Company "LUCHEVAYA DIAGNOSTIKA", Russian Association of Radiologists</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.20862/0042-4676-2016-97-1-33-40</article-id><article-id custom-type="elpub" pub-id-type="custom">rentrad-108</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ СТАТЬИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL RESEARCH</subject></subj-group></article-categories><title-group><article-title>СРАВНИТЕЛЬНЫЙ АНАЛИЗ ДОЗ ОБЛУЧЕНИЯ ПАЦИЕНТОВ ПРИ КОМПЬЮТЕРНОЙ ТОМОГРАФИИ В ФЕДЕРАЛЬНОМ ЛЕЧЕБНОМ УЧРЕЖДЕНИИ</article-title><trans-title-group xml:lang="en"><trans-title>COMPARATIVE SURVEY OF RADIATION DOSES TO PATIENTS IN COMPUTED TOMOGRAPHY IN A FEDERAL HOSPITAL</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Маткевич</surname><given-names>Е. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Matkevich</surname><given-names>Е. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>врач-рентгенолог, преподаватель кафедры авиационной и космической медицины</p></bio><bio xml:lang="en"><p>Radiologist, Teacher of Chair Aviation and Space Medicine</p></bio><email xlink:type="simple">pencil_red@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Синицын</surname><given-names>В. Е.</given-names></name><name name-style="western" xml:lang="en"><surname>Sinitsyn</surname><given-names>V. E.</given-names></name></name-alternatives><bio xml:lang="ru"><p>д. м. н., профессор, руководитель Центра лучевой диагностики ЛРЦ</p></bio><bio xml:lang="en"/><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мершина</surname><given-names>Е. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Mershina</surname><given-names>E. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>к. м. н., заведующая отделением функциональных методов лучевой диагностики Центра лучевой диагностики ЛРЦ</p></bio><bio xml:lang="en"><p>MD, PhD, Head of Department of Functional Tomography of Center of Radiology of Federal Center of Treatment and Rehabilitation</p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГАУ «Лечебно-реабилитационный центр» Министерства здравоохранения РФ&#13;
ГБОУ ВПО «Первый Московский государственный медицинский университет им. И.М. Сеченова» Министерства здравоохранения РФ</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Federal Center of Treatment and Rehabilitation, Ministry of Health of the RF&#13;
I.M. Sechenov First Moscow State Medical University, Ministry of Health of the RF</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГАУ «Лечебно-реабилитационный центр» Министерства здравоохранения РФ</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Federal Center of Treatment and Rehabilitation, Ministry of Health of the RF</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>26</day><month>05</month><year>2016</year></pub-date><volume>97</volume><issue>1</issue><fpage>33</fpage><lpage>39</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Маткевич Е.И., Синицын В.Е., Мершина Е.А., 2016</copyright-statement><copyright-year>2016</copyright-year><copyright-holder xml:lang="ru">Маткевич Е.И., Синицын В.Е., Мершина Е.А.</copyright-holder><copyright-holder xml:lang="en">Matkevich Е.I., Sinitsyn V.E., Mershina E.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.russianradiology.ru/jour/article/view/108">https://www.russianradiology.ru/jour/article/view/108</self-uri><abstract><p>Цель исследования – проанализировать дозы облучения пациентов во время рутинных компьютерно-томографических (КТ) исследований головы, органов грудной клетки (ОГК), брюшной полости (ОБП) и малого таза (ОМТ) в многопрофильном лечебном учреждении и возможные направления их снижения. Материал и методы. Была составлена ретроспективная рандомизированная выборка из электронного архива лечебно- профилактического учреждения «Система передачи и архивации изображений» (PACS) в количестве 1626 исследований (794 мужчины и 832 женщины в возрасте от 17 до 93 лет), про- веденных на трех современных мультиспиральных томографах в течение одного года. Были выбраны КТ-исследования с изображениями хорошего качества, для них регистрировались доза на один срез (CTDI, мГр) и произведение дозы на длину (DLP, мГр*см). Эффективные дозы (мЗв) вычисляли согласно приведенным в МУ 2.6.1.2944-11 нормализованным коэффициентам для каждой из областей. Результаты. Оценена структура КТ-исследований в мно- гопрофильном лечебном учреждении за 2012–2014 гг. Средние дозы облучения (мЗв) пациентов (M±m) по трем КТ-сканерам в сформированной выборке составили соответственно без кон- траста / с контрастом: голова – 2,34 ± 0,03/3,52 ± 0,23, ОГК – 4,83 ± 0,11/11,02 ± 0,82, ОБП + ОМТ – 9,81 ± 0,40/36,6 ± 1,17, ОГК + ОБП + ОМТ – 12,41 ± 0,79/35,63 ± 1,81. Приведены примеры, иллюстрирующие возможность дальнейшего снижения лучевой нагрузки на пациентов с применением КТ с итеративной реконструкцией. Заключение. Средние дозы облучения пациентов при КТ- исследованиях головы, ОГК, ОБП + ОМТ, ОГК + ОБП + ОМТ в многопрофильном лечебном учреждении сопоставимы с данными, приведенными в исследованиях зарубежных авторов. Подобный анализ целесообразно провести в других лечебных учреждениях для дальнейшего определения референтных диагностических уровней, а также для сотрудничества с меж- дународным проектом EUROSAFE projects.</p><p> </p></abstract><trans-abstract xml:lang="en"><p>Objective – to analyze radiation exposure due to computed tomography (CT) of brain, chest, abdomen and pelvis in a large multifield federal hospital and feasibility of low-dose CT-examinations. Material and methods. Retrospective analysis was performed using data from electronic patient records and PACS from a single multi-field hospital. Data were obtained from 1626 records of patients (794 men, 832 women; age range 17–93) scanned with 3 MDCT during one year. CT-examinations of good quality were selected, volumetric CT dose index (CTDI) and dose-length product (DLP) were collected for each of them. The effective doses (ED) were calculated using the normalized coefficients according to Russian Guidance. Results. Number and structure of CT-examinations for the years 2012–2014 in a multi-field hospital were analyzed. The mean effective dose (M±m) values with/without contrast medium (respectively), according to anatomical areas were as follows: brain – 2,34 ± 0,03/3,52 ± 0,23, chest – 4,83 ± 0,11/ 11,02 ± 0,82, abdomen-pelvis – 9,81±0,40/36,6±1,17, chest-abdomen-pelvis – 12,41 ± 0,79/35,63 ± 1,81 mSv. Conclusion. Results of this study give an example of CT dose values and distribution in a multi-field hospital. They are comparable with reference levels published of other authors. This experience should be expanded for creation of CT national reference values and for co-operation with international initiatives (EUROSAFE projects).</p><sec><title> </title><p> </p></sec><sec><title> </title><p> </p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>компьютерная томография</kwd><kwd>радиационная безопасность</kwd><kwd>средние дозы облучения пациентов</kwd><kwd>референтные диагностические уровни</kwd><kwd>снижение дозовой нагрузки</kwd></kwd-group><kwd-group xml:lang="en"><kwd>computed tomography</kwd><kwd>radiation safety</kwd><kwd>mean radiation dose of patients</kwd><kwd>diagnostic reference levels</kwd><kwd>low-dose CT-examinations</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Morin R.L., Seibert J.A., Boone J.M. Radiation dose and safety: Informatics standards and tools. J. Am. Coll. Radiol. 2014; 11 (12 Pt B): 1286–97.</mixed-citation><mixed-citation xml:lang="en">Morin R.L., Seibert J.A., Boone J.M. Radiation dose and safety: Informatics standards and tools. J. Am. Coll. Radiol. 2014; 11 (12 Pt B): 1286–97.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Государственный доклад Роспотребнадзора «О состоянии сани- тарно-эпидемиологического благополучия населения в Российской Федерации в 2011 году». М.: Федеральный центр гигиены и эпидемиологии Роспотребнадзора; 2012: 268–9.</mixed-citation><mixed-citation xml:lang="en">Rospotrebnadzor State report «About the state of sanitary and epidemiological welfare of the population in the Russian Federation in 2011». Moscow; 2012: 268–9 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">МУ 2.6.1.2944-11. 2.6.1. Ионизирующее излучение, радиационная безопасность. Контроль эффективных доз облучения пациентов при проведении медицинских рентгенологических исследований. Методические указания (утв. Роспотребнадзором 19.07.2011). М.; 2011.</mixed-citation><mixed-citation xml:lang="en">MU 2.6.1.2944-11. 2.6.1. Ionizing radiation, radiation safety. Monitoring of the effective doses of patient due to medical x-ray examinations. Guidelines. Moscow; 2011 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Синицын В.Е., Глазкова М.А., Мер- шина Е.А., Архипова И.М. Возможности снижения лучевой на- грузки при проведении МСКТ- коронарографии: использование адаптивной статистической итеративной реконструкции. Ангио- логия и сосудистая хирургия. 2012; 18 (3): 44–9.</mixed-citation><mixed-citation xml:lang="en">Sinitsyn V.E., Glazkova M.A., Mershina E.A., Arkhipova I.M. The possibility of reducing radiation exposure due to CT coronary angiography: the use of adaptive statistical iterative reconstruction. Angiologiya i sosudistaya khirurgiya. 2012; 18 (3): 44–9 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Вишневская А.В., Кондратьев Е.В. Снижение эффективной дозы об- лучения при МСКТ-перфузии головного мозга с использованием итеративных реконструкций. Медицинская визуализация. 2013; 3: 41–51.</mixed-citation><mixed-citation xml:lang="en">Vishnevskaya A.V., Kondrat'ev E.V. The reduction of the effective dose due to MSCT-perfusion of the brain using iterative reconstruction. Meditsinskaya vizualizatsiya. 2013; 3: 41–51 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Smith-Bindman R. Environmental causes of breast cancer and radiation from medical imaging: findings from the Institute of Medicine report. Arch. Intern. Med. 2012; 172 (13): 1023–7.</mixed-citation><mixed-citation xml:lang="en">Smith-Bindman R. Environmental causes of breast cancer and radiation from medical imaging: findings from the Institute of Medicine report. Arch. Intern. Med. 2012; 172 (13): 1023–7.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">European guidelines on quality criteria for computed tomography. Report EUR 16262. Brussels, Belgium: European Commission; 1999.</mixed-citation><mixed-citation xml:lang="en">European guidelines on quality criteria for computed tomography. Report EUR 16262. Brussels, Belgium: European Commission; 1999.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Hayton A., Wallace A., Marks P. et al. Australian diagnostic reference levels for multi detector computed tomography. Australas Phys. Eng. Sci. Med. 2013; 36 (1): 19–26.</mixed-citation><mixed-citation xml:lang="en">Hayton A., Wallace A., Marks P. et al. Australian diagnostic reference levels for multi detector computed tomography. Australas Phys. Eng. Sci. Med. 2013; 36 (1): 19–26.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Van der Molen A.J., Schilham A., Stoop P. et al. National survey on radiation dose in CT in the Netherlands. Insights Imaging. 2013; 4 (3): 383–90.</mixed-citation><mixed-citation xml:lang="en">Van der Molen A.J., Schilham A., Stoop P. et al. National survey on radiation dose in CT in the Netherlands. Insights Imaging. 2013; 4 (3): 383–90.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Tsapaki V., Aldrich J.E., Sharma R. et al. Dose reduction in CT while maintaining diagnostic confidence: diagnostic reference levels at routine head, chest, and abdominal CT – IAEA-coordinated research project. Radiology. 2006; 240 (3): 828–34.</mixed-citation><mixed-citation xml:lang="en">Tsapaki V., Aldrich J.E., Sharma R. et al. Dose reduction in CT while maintaining diagnostic confidence: diagnostic reference levels at routine head, chest, and abdominal CT – IAEA-coordinated research project. Radiology. 2006; 240 (3): 828–34.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">International Atomic Energy Agency. Radiological protection for medical exposure to ionizing radiation safety guide. IAEA safety Standarts Series No. RS-G-1.5, Vienna, Austria: International Atomic Energy Agency; 2002.</mixed-citation><mixed-citation xml:lang="en">International Atomic Energy Agency. Radiological protection for medical exposure to ionizing radiation safety guide. IAEA safety Standarts Series No. RS-G-1.5, Vienna, Austria: International Atomic Energy Agency; 2002.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">МР 2.6.1.0066-12. 2.6.1. Ионизирующее излучение, радиационная безопасность. Применение референтных диагностических уровней для оптимизации радиационной защиты пациента в рентгенологических исследованиях общего назначения: Методические рекомендации (утв. Роспотребнадзором 23.07.2012). М.; 2012.</mixed-citation><mixed-citation xml:lang="en">MR 2.6.1.0066-12. 2.6.1. Ionizing radiation, radiation safety. The application of reference diagnostic levels for optimization of patient’s radiation protection during x-ray examinations of general purpose. Guidelines. Moscow; 2012 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Goldschmidt F., De Gelder P., Beraha D. An approach to knowledge management for EUROSAFE projects: EUROSAFE 2005 «Safety Improvements – Reasons, Strategies, Implementation». Brussels, November 7-8, 2005, Seminar 2. Available at http:// www.eurosafe-forum.org/sites/ default/files/pe_390_24_1_seminar2 _10_2005.pdf.</mixed-citation><mixed-citation xml:lang="en">Goldschmidt F., De Gelder P., Beraha D. An approach to knowledge management for EUROSAFE projects: EUROSAFE 2005 «Safety Improvements – Reasons, Strategies, Implementation». Brussels, November 7-8, 2005, Seminar 2. Available at http:// www.eurosafe-forum.org/sites/ default/files/pe_390_24_1_seminar2 _10_2005.pdf.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
